    Choosing an Independent Ventilation Hygiene Assessor

    Use this checklist when you commission a ventilation hygiene survey, compare quotes, or review a cleaning contractor's proposal. The more boxes a provider ticks, the more confident you can be that you will only pay for the work your systems actually need.

    1. Independence

    • Does the assessor provide cleaning services? If yes, how is the conflict of interest managed?
    • Will the same company inspect, clean and sign off the work?
    • Will you receive a cleaning scope you can take to any contractor for competitive quotes?

    2. Standards and method

    • Do they assess against the current edition — BESA TR19® Air Version 2 (2026), and TR19® Grease for kitchen extract?
    • Do they explain which test method they will use — DTT, vacuum test (EVT) or WFTT — and why?
    • Do they recognise where DTT is not suitable, such as spiral, lined or greasy ductwork?
    • Will they test at enough representative locations — at least three per system, more for larger systems?
    • Will test locations be marked on a plan so they can be re-tested after cleaning?

    3. The report

    • Individual results for every test location, not just a summary.
    • Photographs linked to each location.
    • Classification by system against TR19 criteria.
    • A record of inaccessible areas and limitations.
    • Prioritised recommendations — including which systems do NOT need cleaning.
    • A re-inspection date and verification plan.
    • Ask to see a redacted sample report before you commission the work.

    4. Post-clean verification

    • Will cleaning be verified independently at the same locations as the pre-clean tests?
    • Will the contractor's Post-Work Verification Report be checked, including before-and-after photos and test results?
    • Will each system be given a TR19 v2 outcome: Full Clean, Partial Clean, Inspection (Clean) or Inspection (Not Clean)?

    5. Competence and assurance

    • Health and safety pre-qualification (for example SafeContractor).
    • Professional memberships relevant to occupational and indoor air hygiene (for example BOHS).
    • Appropriate insurance for work in your buildings.
    • Safe working arrangements for access, isolation and working at height, agreed with your team.

    6. Programme management (multi-site clients)

    • A system register for every site.
    • Risk-based inspection intervals rather than one fixed frequency.
    • Exception reporting and close-out tracking.
    • Consistent methods and report format across all sites.
    • An annual summary suitable for client or board reporting.

    7. Reviewing a cleaning quote? Ask these first

    QuestionWhy it matters
    What evidence shows cleaning is needed?A quote should follow measured results, not a fixed interval alone.
    Which systems and sections are included?Vague scopes lead to disputes and partial cleans.
    How will the result be verified — and by whom?Self-certification is not independent evidence.
    Will access panels be needed?Missing access limits both cleaning and verification.
    What will the Post-Work Verification Report contain?TR19 Air v2 sets out what post-clean reporting should include.

    How Green Air Monitoring measures up

    Independent — we do not clean. We assess to BESA TR19® Air Version 2 and TR19® Grease, select DTT, EVT or WFTT to suit each surface, report every result with photographs and limitations, and verify cleaning independently. SafeContractor approved · BOHS Affiliate Member · established 1999 · London and the South East.

    This guide is general information and does not replace BESA TR19® or professional advice for your building. TR19® is a registered trademark of the Building Engineering Services Association.