Guide

    CO₂ Monitoring: The Simplest Indicator of Office Ventilation Performance

    How CO₂ monitoring reveals ventilation adequacy in offices and why it is the first metric facilities managers should track.

    30 March 20261 min read
    Last reviewed:

    Why CO₂ Is the Key Metric

    Carbon dioxide concentration is the single most practical indicator of ventilation performance in occupied spaces. Unlike VOCs or particulates, CO₂ is directly linked to occupancy and ventilation rate — making it an objective, measurable proxy for fresh air provision.

    What Do the Numbers Mean?

    CIBSE Guide A and Building Regulations Part F set clear benchmarks:

    • Below 800 ppm — good ventilation, adequate fresh air supply
    • 800–1,000 ppm — acceptable but approaching the threshold; ventilation should be reviewed
    • 1,000–1,500 ppm — indicates inadequate ventilation; occupants may experience drowsiness and reduced concentration
    • Above 1,500 ppm — poor ventilation requiring immediate corrective action

    Common Causes of Elevated CO₂

    In our 27 years of assessing commercial buildings, the most frequent causes we encounter include:

    • AHU fresh air dampers set incorrectly or stuck closed
    • Demand-controlled ventilation systems miscalibrated
    • Rooms repurposed for higher occupancy without ventilation adjustment
    • Building management system (BMS) faults or overrides

    What to Do About It

    Regular CO₂ monitoring — either spot-check or continuous — provides the evidence needed to identify underperforming ventilation zones and take corrective action before complaints arise. Green Air Monitoring provides both one-off assessments and ongoing monitoring programmes as part of our IAQ assurance contracts.

    co2ventilationoffice-air-quality

    Related Resources

    Guide

    When Smoke Outlasts the Fire: A UK Perspective on Persistent Air Pollution

    Researchers at Bristol have found that a pollutant in wildfire smoke can resist being broken down by sunlight. That challenges the idea that smoke clears as soon as the fire is out. This article explains what the study does and doesn’t show. It also covers how UK organisations can prepare for smoke incidents, read air quality information correctly and scope indoor air quality assessments so they answer the questions that remain.

    Guide

    After the Cooking Stops: The Air Quality Question Facing UK Kitchens

    Cooking ends at a recognisable moment, but the airborne material it produces may not behave so simply. Recent research led by the University of Birmingham shows that cooking-related aerosols can behave in unexpected ways. It doesn’t set a clearance time for working kitchens, but it does raise a practical question for UK building managers. Does your kitchen assessment cover the whole cooking event? That means conditions before preparation, during service and after the heat is turned off, including any effect on neighbouring spaces and the staff who stay behind to clean and close.

    Guide

    Beyond the Hearth: What Birmingham’s Wood-Smoke Research Means for UK Buildings

    Wood burning remains an important part of the air pollution picture in Birmingham, with implications that extend beyond the homes where fires are lit. Research highlighted by the University of Birmingham in December 2024 offers a useful starting point for a wider question: how should the people responsible for UK buildings investigate fine particles arriving from outside?

    Need Indoor Air Quality Testing?

    Get a no-obligation quote. We provide IAQ testing, ventilation assessment and environmental monitoring across London and the South East.

    We use cookies to measure how our site and adverts perform. You can accept or reject non-essential cookies. Privacy policy