Ventilation Hygiene PPM Contracts for FM Portfolios

    Ventilation Hygiene PPM Contracts for FM Portfolios

    Independent ventilation hygiene assessors · Focused on impartial evidence

    Last reviewed:

    A ventilation hygiene PPM contract turns one-off surveys into a managed, evidence-led programme across your portfolio. We schedule risk-based TR19 assessments, flag exceptions early, verify any cleaning independently and give you the reporting your clients and auditors expect.

    Established 1999 · 2,500+ assessments · SafeContractor approved · BOHS Affiliate Member · London & South East

    Who it is for

    The programme is built for organisations managing several buildings or systems.

    • Facilities management companies
    • Managing agents
    • Multi-site corporate occupiers
    • Estates teams
    • Retail, hospitality and leisure portfolios

    How the programme works

    Each contract follows the same seven-stage cycle.

    1. Asset and data review

      We review asset lists, drawings and previous reports to build a system register for each site.

    2. Site categorisation

      We categorise systems by type, use and risk.

    3. Risk-based intervals

      We set inspection intervals for each system in line with TR19 Air and TR19 Grease, and any contract or insurer requirement.

    4. Scheduled surveys

      Assessments are scheduled and delivered to a consistent method and reporting format across every site.

    5. Exception reporting

      Systems that fail the criteria are flagged promptly, with a defined cleaning scope.

    6. Independent verification

      After cleaning by your contractor, we verify the result against the pre-clean evidence.

    7. Annual management review

      We review the year's findings with you and adjust intervals and priorities.

    What you receive

    You get a complete evidence record for the portfolio.

    • Asset and system register for each site
    • Planned inspection schedule
    • Service history record by system
    • Evidence summary showing status across the portfolio
    • Exception list with priorities and close-out status
    • Budget forecast for likely cleaning and remedial works
    • Annual summary suitable for board or client reporting

    Contract KPIs

    We report against agreed KPIs.

    Typical KPIs we report against
    KPIWhat it shows
    Survey completionPlanned surveys delivered on schedule
    Report turnaroundReports issued within the agreed timescale
    High-risk escalationCritical findings notified within the agreed timescale
    Close-out verificationRemedial works verified after completion
    Data completenessEvery system has a current record and next due date

    Swipe sideways to see the full table →

    What this contract covers — and what it doesn't

    Ventilation hygiene, indoor air quality and fire-damper testing are connected but not interchangeable. We are clear about what each part of your programme covers.

    AreaIncluded in ventilation hygiene PPM?
    Ductwork and AHU hygiene condition (TR19 Air)Yes
    Kitchen extract grease condition (TR19 Grease)Yes, where included in scope
    Independent post-clean verificationYes
    Indoor air quality testingAvailable as a combined contract
    Duct cleaningNo — we are independent and do not clean
    Fire-damper drop testingNot included — arranged separately

    Swipe sideways to see the full table →

    Independent post-clean verification to TR19 Air Version 2

    Version 2 of TR19 Air (March 2026) formalises what should be reported after cleaning. When your contractor has finished, we check the work independently rather than relying on self-certification.

    • We re-test at the same locations as the pre-clean survey, using the same method
    • We review the contractor's Post-Work Verification Report, including before-and-after photographs, test results, site plan and access-point details
    • We confirm the outcome for each system: Full Clean, Partial Clean, Inspection (Outcome 'Clean') or Inspection (Outcome 'Not Clean')

    Limitations and what this assessment cannot tell you

    • The programme covers the systems and sites listed in the contract register
    • Cleaning and remedial works are carried out by your contractors, not by us
    • Results for each system reflect the date of its last survey

    What portfolio reporting includes

    • Portfolio status summary by site and system
    • Next due dates and overdue items
    • Exceptions, priorities and close-out status
    • Individual site reports with photographs and results
    • Annual trend review

    Plan a multi-site ventilation hygiene programme

    Free, no-obligation — we aim to reply promptly during business hours.

    🔒 Your details are private and never shared with third parties.

    Frequently Asked Questions

    Pricing is based on the number of sites and systems, assessment frequency and geographic spread. We provide fixed annual pricing so you can budget with certainty.

    Yes. We offer combined contracts that cover indoor air quality surveys and TR19 assessments under one agreement and one reporting format.

    No. We assess, specify and verify. You appoint the cleaning contractor, and we confirm independently that the work meets the required standard.

    We can supply results in a format that suits your system. We agree the format at the start of the contract.

    London, Kent, Surrey, Essex, Sussex, Hertfordshire, Berkshire and the wider South East.

    Need Indoor Air Quality Testing?

    Get a no-obligation quote. We provide IAQ testing, ventilation assessment and environmental monitoring across London and the South East.